Účinek redukovaného glutathionu, povrchově aktivních látek a iontové síly na detekci metalothioneinů stanovených Brdičkovou reakcí
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F67985904%3A_____%2F09%3A00325004" target="_blank" >RIV/67985904:_____/09:00325004 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Effect of reduced glutathione, surface active agents, and ionic strength on the detection of metallothioneins by using of Brdicka reaction
Popis výsledku v původním jazyce
We investigated the effects of two surface active agents (sodium dodecyl sulfate, SDS, and polyoxyethylene sorbitol, Tween-20), ionic strength and reduced glutathione (GSH) on metallothionein (MT) signals measured by adsorptive transfer stripping differential pulse voltammetry Brdicka reaction. The MT signal was more than two hundred times higher than the GSH one at the accumulation time of 120s. The influence of Tween-20 was investigated in a broad concentration range (from 10-8 to 10-11 %, v/v). We found that the catalytic Cat2 signal decreased for more than 60% with increasing Tween-20 content. In the case of using SDS (10-3 ? 10-6 M), the increase of Cat2 peak in the presence of the highest SDS concentration was determined. The height of Cat2 peakenhanced with increasing ionic strength mimicking by NaCl concentration. Based on the enhancement of the Cat2 peak we determined the ionic strength of fibroblast samples and recalculated the concentration of MT determined there.
Název v anglickém jazyce
Effect of reduced glutathione, surface active agents, and ionic strength on the detection of metallothioneins by using of Brdicka reaction
Popis výsledku anglicky
We investigated the effects of two surface active agents (sodium dodecyl sulfate, SDS, and polyoxyethylene sorbitol, Tween-20), ionic strength and reduced glutathione (GSH) on metallothionein (MT) signals measured by adsorptive transfer stripping differential pulse voltammetry Brdicka reaction. The MT signal was more than two hundred times higher than the GSH one at the accumulation time of 120s. The influence of Tween-20 was investigated in a broad concentration range (from 10-8 to 10-11 %, v/v). We found that the catalytic Cat2 signal decreased for more than 60% with increasing Tween-20 content. In the case of using SDS (10-3 ? 10-6 M), the increase of Cat2 peak in the presence of the highest SDS concentration was determined. The height of Cat2 peakenhanced with increasing ionic strength mimicking by NaCl concentration. Based on the enhancement of the Cat2 peak we determined the ionic strength of fibroblast samples and recalculated the concentration of MT determined there.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CG - Elektrochemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2009
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Electroanalysis
ISSN
1040-0397
e-ISSN
—
Svazek periodika
21
Číslo periodika v rámci svazku
3-5
Stát vydavatele periodika
DE - Spolková republika Německo
Počet stran výsledku
5
Strana od-do
—
Kód UT WoS článku
000264063500057
EID výsledku v databázi Scopus
—