Contrast Mechanisms in the Scanning Low Energy Electron Microscopy.
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68081731%3A_____%2F03%3A12030024" target="_blank" >RIV/68081731:_____/03:12030024 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Contrast Mechanisms in the Scanning Low Energy Electron Microscopy.
Popis výsledku v původním jazyce
The SEM instruments, marketed at the present time, cover the range of impact energies of primary electrons down to 1 keV. Systems with compound objective lenses, containing a retarding field element, extend this range down to about 200 eV and the cathodelens (CL) equipped devices allow using arbitrarily low impact energy at acceptable resolution [1]. Consequently, the electron energy becomes a mere parameter of the SEM image and all contrast mechanisms, excited by electron impact, appear as equally available. Similarly, the strict distinguishing between kinds of information mediated by seconary (SE) and backscattered (BSE) electrons, respectively, is less relevant with novel detector principles employing acceleration of emitted electrons and conversion of accelerated signal species to slow SE. A CL equipped SEM detects SE and BSE together so that both should be always considered with any particular family of contrasts.
Název v anglickém jazyce
Contrast Mechanisms in the Scanning Low Energy Electron Microscopy.
Popis výsledku anglicky
The SEM instruments, marketed at the present time, cover the range of impact energies of primary electrons down to 1 keV. Systems with compound objective lenses, containing a retarding field element, extend this range down to about 200 eV and the cathodelens (CL) equipped devices allow using arbitrarily low impact energy at acceptable resolution [1]. Consequently, the electron energy becomes a mere parameter of the SEM image and all contrast mechanisms, excited by electron impact, appear as equally available. Similarly, the strict distinguishing between kinds of information mediated by seconary (SE) and backscattered (BSE) electrons, respectively, is less relevant with novel detector principles employing acceleration of emitted electrons and conversion of accelerated signal species to slow SE. A CL equipped SEM detects SE and BSE together so that both should be always considered with any particular family of contrasts.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2003
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Microscopy and Microanalysis
ISSN
1431-9276
e-ISSN
—
Svazek periodika
9
Číslo periodika v rámci svazku
Sup. 3
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
2
Strana od-do
120-121
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—