Scintilační detektor v environmentální SEM
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68081731%3A_____%2F05%3A00022402" target="_blank" >RIV/68081731:_____/05:00022402 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Scintillation Detector in Environmental SEM
Popis výsledku v původním jazyce
The article deals with the concept of secondary electron scintillation detector in Environmental SEM. For secondary electrons detection by scintillation detector, the voltage of about 10 kV attached to the conductive surface layer of the scintillator accelerates secondary electrons to give them sufficient energy for efficient scintillation. However, presence of this voltage requires pressure less than 5 Pa in the scintillator room to avoid discharges. Therefore, our design of secondary electron detectoris based on scintillator location in a room with low pressure. This room is separated from the specimen chamber by the system of pressure limiting apertures that allow pass secondary electrons and inhibit the gas flow. The rooms between the apertures and scintillator are vacuum pumped. The results show that this detector provides new possibilities of electrons detection in Environmental SEM.
Název v anglickém jazyce
Scintillation Detector in Environmental SEM
Popis výsledku anglicky
The article deals with the concept of secondary electron scintillation detector in Environmental SEM. For secondary electrons detection by scintillation detector, the voltage of about 10 kV attached to the conductive surface layer of the scintillator accelerates secondary electrons to give them sufficient energy for efficient scintillation. However, presence of this voltage requires pressure less than 5 Pa in the scintillator room to avoid discharges. Therefore, our design of secondary electron detectoris based on scintillator location in a room with low pressure. This room is separated from the specimen chamber by the system of pressure limiting apertures that allow pass secondary electrons and inhibit the gas flow. The rooms between the apertures and scintillator are vacuum pumped. The results show that this detector provides new possibilities of electrons detection in Environmental SEM.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GA102%2F05%2F0886" target="_blank" >GA102/05/0886: Výzkum detekčních systémů pravých sekundárních elektronů v nově koncipovaném environmentálním rastrovacím elektronovém mikroskopu</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2005
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings - Microscopy Conference 2005 - Dreiländertagung /6./
ISBN
1019-6447
ISSN
—
e-ISSN
—
Počet stran výsledku
1
Strana od-do
44
Název nakladatele
Paul Scherrer Institute
Místo vydání
Villigen
Místo konání akce
Davos
Datum konání akce
28. 8. 2005
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—