Strategie sběru sekundárních elektronů v REM
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68081731%3A_____%2F07%3A00089380" target="_blank" >RIV/68081731:_____/07:00089380 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Strategies for Collection of Secondary Electrons in the SEM
Popis výsledku v původním jazyce
The standard way of secondary electron (SE) detection in the scanning electron microscope (SEM) is to use the Everhart-Thornley (ET) detector. Only weak electrostatic field attracts low energy SEs. Let us call this system the standard detector. Althoughthe ET detector has been around for more than fifty years, it remains the most frequently used type of detector in SEMs. Modern SEMs have improved their image resolution by so called immersion systems, allowing a strong magnetic field of the objective lens to penetrate into the specimen region. In that case, two ET detectors are usually used: one is located above the objective lens, and the other below it (upper and lower detector). The resulting contrast of the SE images depends on SE energy and on theangular sensitivity of detectors, which is a result of specific distributions of electrostatic and magnetic fields in the specimen region.
Název v anglickém jazyce
Strategies for Collection of Secondary Electrons in the SEM
Popis výsledku anglicky
The standard way of secondary electron (SE) detection in the scanning electron microscope (SEM) is to use the Everhart-Thornley (ET) detector. Only weak electrostatic field attracts low energy SEs. Let us call this system the standard detector. Althoughthe ET detector has been around for more than fifty years, it remains the most frequently used type of detector in SEMs. Modern SEMs have improved their image resolution by so called immersion systems, allowing a strong magnetic field of the objective lens to penetrate into the specimen region. In that case, two ET detectors are usually used: one is located above the objective lens, and the other below it (upper and lower detector). The resulting contrast of the SE images depends on SE energy and on theangular sensitivity of detectors, which is a result of specific distributions of electrostatic and magnetic fields in the specimen region.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/KJB200650501" target="_blank" >KJB200650501: Detekce signálních elektronů při nízkých energiích primárního svazku v rastrovací elektronové mikroskopii</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2007
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Microscopy and Microanalysis
ISSN
1431-9276
e-ISSN
—
Svazek periodika
13
Číslo periodika v rámci svazku
Suppl. 3
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
2
Strana od-do
78-79
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—