Vliv magnetické susceptibility a elektrické vodivosti kovových dentálních materiálů na velikost artefaktů v MR obrazech
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68081731%3A_____%2F08%3A00308386" target="_blank" >RIV/68081731:_____/08:00308386 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216208:11110/08:73 RIV/00064165:_____/08:73
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Magnetic susceptibility and electrical conductivity of metallic dental materials and their impact on MR imaging artifacts
Popis výsledku v původním jazyce
The aim of this study was to test the hypothesis that dental materials vary significantly in MR-relevant material parameters?magnetic susceptibility and electrical conductivity, and that knowledge of these parameters may be used to estimate the quality of MR imaging in the presence of devices made of such materials. For typical dental devices, magnetic susceptibility differences were found of little clinical importance for diagnostic SE/GE imaging of the neck and brain, but significant for orofacial imaging. Short-TE GE imaging has been found possible even in very close distances from dental devices made of amalgams, precious alloys and titanium alloys. Nickel?chromium and cobalt?chromium artifacts were found still acceptable, but large restorations ofaluminum bronzes may preclude imaging of the orofacial region. The influence of electrical conductivity on the artifact size was found negligible.
Název v anglickém jazyce
Magnetic susceptibility and electrical conductivity of metallic dental materials and their impact on MR imaging artifacts
Popis výsledku anglicky
The aim of this study was to test the hypothesis that dental materials vary significantly in MR-relevant material parameters?magnetic susceptibility and electrical conductivity, and that knowledge of these parameters may be used to estimate the quality of MR imaging in the presence of devices made of such materials. For typical dental devices, magnetic susceptibility differences were found of little clinical importance for diagnostic SE/GE imaging of the neck and brain, but significant for orofacial imaging. Short-TE GE imaging has been found possible even in very close distances from dental devices made of amalgams, precious alloys and titanium alloys. Nickel?chromium and cobalt?chromium artifacts were found still acceptable, but large restorations ofaluminum bronzes may preclude imaging of the orofacial region. The influence of electrical conductivity on the artifact size was found negligible.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
FF - ORL, oftalmologie, stomatologie
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/NR8110" target="_blank" >NR8110: Dentální slitiny a jejich kompatibilita s vyšetřením metodou magnetické rezonance</a><br>
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2008
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Dental Materials
ISSN
0109-5641
e-ISSN
—
Svazek periodika
24
Číslo periodika v rámci svazku
6
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
9
Strana od-do
715-723
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—