Scintillation SE detector for variable pressure scanning electron microscopes
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68081731%3A_____%2F10%3A00350812" target="_blank" >RIV/68081731:_____/10:00350812 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216305:26220/10:PU88618
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Scintillation SE detector for variable pressure scanning electron microscopes
Popis výsledku v původním jazyce
We present results obtained with a new scintillation detector of secondary electrons for the variable pressure scanning electron microscope. A detector design is based on the positioning of a single crystal scintillator within a scintillator chamber separated from the specimen chamber by two apertures. This solution enables us to decrease the pressure to several Pa in the scintillator chamber while the pressure in the specimen chamber reaches values of about 1000 Pa (7.5 Torr). Due to decreased pressure, we can apply a potential of the order of several kV to the scintillator, which is necessary for the detection of secondary electrons. Simultaneously, the two apertures at appropriate potentials of the order of several hundreds of volts create an electrostatic lens that allows electrons to pass from the specimen chamber to the scintillator chamber. Results indicate a promising utilization of this detector for a wide range of specimen observations.
Název v anglickém jazyce
Scintillation SE detector for variable pressure scanning electron microscopes
Popis výsledku anglicky
We present results obtained with a new scintillation detector of secondary electrons for the variable pressure scanning electron microscope. A detector design is based on the positioning of a single crystal scintillator within a scintillator chamber separated from the specimen chamber by two apertures. This solution enables us to decrease the pressure to several Pa in the scintillator chamber while the pressure in the specimen chamber reaches values of about 1000 Pa (7.5 Torr). Due to decreased pressure, we can apply a potential of the order of several kV to the scintillator, which is necessary for the detection of secondary electrons. Simultaneously, the two apertures at appropriate potentials of the order of several hundreds of volts create an electrostatic lens that allows electrons to pass from the specimen chamber to the scintillator chamber. Results indicate a promising utilization of this detector for a wide range of specimen observations.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GAP102%2F10%2F1410" target="_blank" >GAP102/10/1410: Studium vlivu magnetického a elektrostatického pole na zesílení signálu sekundárních elektronů detekovaných novým detektorem pro VP-SEM.</a><br>
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2010
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Microscopy
ISSN
0022-2720
e-ISSN
—
Svazek periodika
239
Číslo periodika v rámci svazku
3
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
6
Strana od-do
—
Kód UT WoS článku
000280994900007
EID výsledku v databázi Scopus
—