Time-resolved plasma parameters in the HiPIMS discharge with Ti target in Ar/O2 atmosphere
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68378271%3A_____%2F11%3A00364640" target="_blank" >RIV/68378271:_____/11:00364640 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1016/j.surfcoat.2010.11.050" target="_blank" >http://dx.doi.org/10.1016/j.surfcoat.2010.11.050</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.surfcoat.2010.11.050" target="_blank" >10.1016/j.surfcoat.2010.11.050</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Time-resolved plasma parameters in the HiPIMS discharge with Ti target in Ar/O2 atmosphere
Popis výsledku v původním jazyce
A High Power Impulse Magnetron Sputtering System(HiPIMS) equipped with a titanium target 5 cm in diameter has been investigated by means of a time-resolved Langmuir probe and time-resolved ion flux probe. The plasma parameters have been measured in a distance of 70 mm from the target face and below the racetrack. The ion flux at the substrate (placed at the same position as the Langmuir probe) has been determined from the voltage drop across a resistor connected with the planar probe. The planar probe was pulsed at a repetition rate of 50 kHz, duty cycle 50%. The effects of working gas pressure and mean discharge current have been investigated.
Název v anglickém jazyce
Time-resolved plasma parameters in the HiPIMS discharge with Ti target in Ar/O2 atmosphere
Popis výsledku anglicky
A High Power Impulse Magnetron Sputtering System(HiPIMS) equipped with a titanium target 5 cm in diameter has been investigated by means of a time-resolved Langmuir probe and time-resolved ion flux probe. The plasma parameters have been measured in a distance of 70 mm from the target face and below the racetrack. The ion flux at the substrate (placed at the same position as the Langmuir probe) has been determined from the voltage drop across a resistor connected with the planar probe. The planar probe was pulsed at a repetition rate of 50 kHz, duty cycle 50%. The effects of working gas pressure and mean discharge current have been investigated.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
BH - Optika, masery a lasery
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2011
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Surface and Coatings Technology
ISSN
0257-8972
e-ISSN
—
Svazek periodika
205
Číslo periodika v rámci svazku
2
Stát vydavatele periodika
CH - Švýcarská konfederace
Počet stran výsledku
4
Strana od-do
"S317"-"S321"
Kód UT WoS článku
000293258600068
EID výsledku v databázi Scopus
—