Electrochemical Migration Issues Related to Improper Solder Mask Application
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21230%2F22%3A00358706" target="_blank" >RIV/68407700:21230/22:00358706 - isvavai.cz</a>
Výsledek na webu
<a href="https://doi.org/10.1109/ISSE54558.2022.9812811" target="_blank" >https://doi.org/10.1109/ISSE54558.2022.9812811</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1109/ISSE54558.2022.9812811" target="_blank" >10.1109/ISSE54558.2022.9812811</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Electrochemical Migration Issues Related to Improper Solder Mask Application
Popis výsledku v původním jazyce
This work aimed to analyze a reliability issue that occurred on printed circuit boards (PCB) primarily designed to study electrochemical migration (ECM) phenomena. The test boards were supplied directly from the PCB producer, and the copper traces were covered with a hot air solder leveling (HASL) surface finish. However, the solder layer was clearly inconsistent and poor, caused by contamination from improper solder mask application, as was confirmed by analysis using the scanning electron microscope. On these boards, a water drop test with distilled water (bias voltage of 10 V) and thermal humidity bias test (85 °C/90% R.H./25 V/168 h) was conducted to evaluate predisposition for electrochemical migration of boards with a such poorly fabricated solder mask. PCB without solder mask and with correctly applied solder mask was also included in this study for comparison. The results clearly showed that the test boards with the poorly fabricated solder mask were significantly more inclinable to electrochemical migration – in the case of the water drop test, the forming dendritic structures shorted the electrodes up to 6 times faster than on PCB without a solder mask, while the samples with correct solder mask exhibited the best resistance against ECM. During the thermal humidity bias test, the electrical short appeared after only 2 hours on PCB with the bad solder mask compared to PCB without the mask, where the dendrites grew after more than 27 hours. Energy dispersive spectroscopy confirmed that the migrating element was tin from the HASL cover layer.
Název v anglickém jazyce
Electrochemical Migration Issues Related to Improper Solder Mask Application
Popis výsledku anglicky
This work aimed to analyze a reliability issue that occurred on printed circuit boards (PCB) primarily designed to study electrochemical migration (ECM) phenomena. The test boards were supplied directly from the PCB producer, and the copper traces were covered with a hot air solder leveling (HASL) surface finish. However, the solder layer was clearly inconsistent and poor, caused by contamination from improper solder mask application, as was confirmed by analysis using the scanning electron microscope. On these boards, a water drop test with distilled water (bias voltage of 10 V) and thermal humidity bias test (85 °C/90% R.H./25 V/168 h) was conducted to evaluate predisposition for electrochemical migration of boards with a such poorly fabricated solder mask. PCB without solder mask and with correctly applied solder mask was also included in this study for comparison. The results clearly showed that the test boards with the poorly fabricated solder mask were significantly more inclinable to electrochemical migration – in the case of the water drop test, the forming dendritic structures shorted the electrodes up to 6 times faster than on PCB without a solder mask, while the samples with correct solder mask exhibited the best resistance against ECM. During the thermal humidity bias test, the electrical short appeared after only 2 hours on PCB with the bad solder mask compared to PCB without the mask, where the dendrites grew after more than 27 hours. Energy dispersive spectroscopy confirmed that the migrating element was tin from the HASL cover layer.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20201 - Electrical and electronic engineering
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2022
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
2022 45th International Spring Seminar on Electronics Technology (ISSE)
ISBN
978-1-6654-6589-2
ISSN
2161-2528
e-ISSN
2161-2536
Počet stran výsledku
6
Strana od-do
—
Název nakladatele
IEEE Press
Místo vydání
New York
Místo konání akce
Vienna
Datum konání akce
11. 5. 2022
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000853642200054