Influence of Current Pulses on Resistance of Conductive Adhesive Joints
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21230%2F22%3A00362943" target="_blank" >RIV/68407700:21230/22:00362943 - isvavai.cz</a>
Výsledek na webu
<a href="https://doi.org/10.1109/Diagnostika55131.2022.9905172" target="_blank" >https://doi.org/10.1109/Diagnostika55131.2022.9905172</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1109/Diagnostika55131.2022.9905172" target="_blank" >10.1109/Diagnostika55131.2022.9905172</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Influence of Current Pulses on Resistance of Conductive Adhesive Joints
Popis výsledku v původním jazyce
Adhesive conductive joints were formed from two types of electrically conductive adhesives with isotropic electrical conductivity and loaded first climatically, and then by current pulses. Climatic loading was carried out for one group of joints at normal temperature and 99 % relative humidity and for the other group at a temperature of 85 oC and relative humidity of 85 %. The exposure time was always 300 hours. Then the joints were loaded with current pulses with a frequency of 50 Hz for 20, 50, and 100 minutes. The amplitudes of the current pulses were 5, 15, and 40 A, respectively. Climatic loading caused only small changes in the resistance of the joints. The same applies to current pulse loading.
Název v anglickém jazyce
Influence of Current Pulses on Resistance of Conductive Adhesive Joints
Popis výsledku anglicky
Adhesive conductive joints were formed from two types of electrically conductive adhesives with isotropic electrical conductivity and loaded first climatically, and then by current pulses. Climatic loading was carried out for one group of joints at normal temperature and 99 % relative humidity and for the other group at a temperature of 85 oC and relative humidity of 85 %. The exposure time was always 300 hours. Then the joints were loaded with current pulses with a frequency of 50 Hz for 20, 50, and 100 minutes. The amplitudes of the current pulses were 5, 15, and 40 A, respectively. Climatic loading caused only small changes in the resistance of the joints. The same applies to current pulse loading.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20201 - Electrical and electronic engineering
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2022
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
2022 International Conference on Diagnostics in Electrical Engineering (Diagnostika)
ISBN
978-1-6654-8082-6
ISSN
—
e-ISSN
—
Počet stran výsledku
6
Strana od-do
169-174
Název nakladatele
Institute of Electrical and Electronics Engineers, Inc.
Místo vydání
—
Místo konání akce
Plzeň
Datum konání akce
6. 9. 2022
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—