Evaluation and Simulation of Ultra-Wide Band (UWB) Transceiver Timebases
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21230%2F25%3A00383325" target="_blank" >RIV/68407700:21230/25:00383325 - isvavai.cz</a>
Výsledek na webu
<a href="https://doi.org/10.3390/engproc2025088040" target="_blank" >https://doi.org/10.3390/engproc2025088040</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.3390/engproc2025088040" target="_blank" >10.3390/engproc2025088040</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Evaluation and Simulation of Ultra-Wide Band (UWB) Transceiver Timebases
Popis výsledku v původním jazyce
Ultra-Wide Band (UWB) real-time localization systems usually require either precise and robust synchronization of the anchor transceivers or sufficiently stable clocks for methods referred to as “synchronization-free”. Typically, reasonably priced crystals or TCXOs are utilized as frequency references for the UWB transceivers. Clock characterization and simulation are necessary to evaluate and tune the synchronization or positioning algorithms without the need of hardware-pulling of the UWB reference oscillators. In this paper, the method of transceiver clock stability measurement is presented, and several modules with various clock sources are evaluated. As a reference, a UWB module with a clock derived from a Caesium standard is utilized. A method for simulating typical timestamp-series errors attributed to UWB transceiver clocks is provided as well.
Název v anglickém jazyce
Evaluation and Simulation of Ultra-Wide Band (UWB) Transceiver Timebases
Popis výsledku anglicky
Ultra-Wide Band (UWB) real-time localization systems usually require either precise and robust synchronization of the anchor transceivers or sufficiently stable clocks for methods referred to as “synchronization-free”. Typically, reasonably priced crystals or TCXOs are utilized as frequency references for the UWB transceivers. Clock characterization and simulation are necessary to evaluate and tune the synchronization or positioning algorithms without the need of hardware-pulling of the UWB reference oscillators. In this paper, the method of transceiver clock stability measurement is presented, and several modules with various clock sources are evaluated. As a reference, a UWB module with a clock derived from a Caesium standard is utilized. A method for simulating typical timestamp-series errors attributed to UWB transceiver clocks is provided as well.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20202 - Communication engineering and systems
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2025
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Engineering Proceeedings, European Navigation Conference 2024 (ENC2024)
ISBN
—
ISSN
2673-4591
e-ISSN
2673-4591
Počet stran výsledku
10
Strana od-do
1-10
Název nakladatele
Multidisciplinary Digital Publishing Institute (MDPI AG)
Místo vydání
Basel
Místo konání akce
Noordwijk
Datum konání akce
22. 5. 2024
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—