Occurrence of Indoor VOCs in Nursery School - Case Study
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F75081431%3A_____%2F17%3A00001171" target="_blank" >RIV/75081431:_____/17:00001171 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Occurrence of Indoor VOCs in Nursery School - Case Study
Popis výsledku v původním jazyce
Children's exposure to air pollutants is an important public health challenge. Particular attention should be paid to preschools because younger children are more vulnerable to air pollution than higher grade children and spend more time indoors. The concentrations of volatile organic compounds (VOCs) as well as carbon dioxide (CO2) concentrations in younger and older children's classrooms during the winter season were studied. An electronic nose based on gas chromatography was used for the analysis of individual VOCs and a photoionization detector with a UV lamp was used for the determination of total volatile organic compounds (TVOC) concentration. Continuous measurements of CO2 concentrations both inside classrooms and outside each building were performed using automatic portable monitors. Improving ventilation, decreasing the occupancy per room and completing cleaning activities following occupancy periods can contribute to alleviating high CO2 and VOCs occurrence levels.
Název v anglickém jazyce
Occurrence of Indoor VOCs in Nursery School - Case Study
Popis výsledku anglicky
Children's exposure to air pollutants is an important public health challenge. Particular attention should be paid to preschools because younger children are more vulnerable to air pollution than higher grade children and spend more time indoors. The concentrations of volatile organic compounds (VOCs) as well as carbon dioxide (CO2) concentrations in younger and older children's classrooms during the winter season were studied. An electronic nose based on gas chromatography was used for the analysis of individual VOCs and a photoionization detector with a UV lamp was used for the determination of total volatile organic compounds (TVOC) concentration. Continuous measurements of CO2 concentrations both inside classrooms and outside each building were performed using automatic portable monitors. Improving ventilation, decreasing the occupancy per room and completing cleaning activities following occupancy periods can contribute to alleviating high CO2 and VOCs occurrence levels.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
50300 - Education
Návaznosti výsledku
Projekt
—
Návaznosti
N - Vyzkumna aktivita podporovana z neverejnych zdroju
Ostatní
Rok uplatnění
2017
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
IOP Conference Series: Materials Science and Engineering
ISBN
—
ISSN
1757-8981
e-ISSN
—
Počet stran výsledku
6
Strana od-do
—
Název nakladatele
Institute of Physics Publishing
Místo vydání
Spojené království
Místo konání akce
Praha
Datum konání akce
12. 6. 2017
Typ akce podle státní příslušnosti
CST - Celostátní akce
Kód UT WoS článku
—